您好,欢迎来到试剂仪器网! [登录] [免费注册]
试剂仪器网
位置:首页 > 品牌 > Sigma-Aldrich > Opticap XL 5 Millipore Express PHF 无菌 0.2 μm 1-1/2 in.TC-1 in.HB

Opticap® XL5 Millipore Express® PHF

Opticap XL 5 Millipore Express PHF 无菌 0.2 μm 1-1/2 in.TC-1 in.HB

品牌
Millipore
货号
KPGES05TB1
规格纯度
sterile, inlet connection diam. 1.5 in., pore size 0.2 μm, cartridge nominal length 5 in. (12.5 cm)
价格
1899.53 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
-+
产品名称:
Opticap® XL5 Millipore Express® PHF
Opticap XL 5 Millipore Express PHF Sterile 0.2 μm 1-1/2 in. TC-1 in. HB
Opticap XL 5 Millipore Express PHF 无菌 0.2 μm 1-1/2 in.TC-1 in.HB
产品介绍:

产品说明

一般描述

Device Configuration: 取样皿滤膜
Sterile capsules meet current USP and AAMI guidelines for sterility utilizing a validated sterilization cycle.

包装

Double Easy-Open bag

其他说明

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

制备说明

This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Sterilization Method
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable

分析说明

Bacterial Retention
Samples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 6.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L

法律信息

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

免责声明

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.

产品性质

质量水平400
物料polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
reg. compliancemeets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
无菌性sterile
特点hydrophilic
manufacturer/tradenameMillipore Express®
参数≤17.4 mL/min air diffusion at 2.8 bar (40 psig) and 23 ℃ (in water)
1.0 bar max. inlet pressure (15 psi) at 80 ℃
1000 bar max. differential pressure (15 psi) at 80 ℃
2.75 bar max. inlet pressure (40 psi) at 60 ℃
25 ℃ max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 ℃
5500 mbar max. differential pressure (80 psi) at 25 ℃
80 psig max. inlet pressure
长度21.6 cm (8.5 in.)
cartridge nominal length5 in. (12.5 cm)
直径10.7 cm (4.2 in.)
过滤面积0.31 m2
inlet connection diam.1.5 in.
inlet to outlet W21.6 cm (8.5 in.)
outlet connection diam.1 in.
总尺寸5 in.
杂质≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
基质Millipore Express® PHF
孔径0.2 μm nominal pore size
0.2 μm pore size
配件1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
38 mm (1 1/2 in.) inlet sanitary flange
outlet hose barb
25 mm (1 in.) outlet hose barb

Sigma-Aldrich

推荐产品