您好,欢迎来到试剂仪器网! [登录] [免费注册]
试剂仪器网
位置:首页 > 品牌 > Sigma-Aldrich > α-Secretase Activity Kit, TNF-α Converting Enzyme Activity Kit, ADAM17 Activity Kit

InnoZyme TACE Activity Kit

α-Secretase Activity Kit, TNF-α Converting Enzyme Activity Kit, ADAM17 Activity Kit

品牌
Sigma-Aldrich
货号
CBA042
包装型号
规格纯度
参考价格
11300 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
-+
产品名称:
InnoZyme TACE Activity Kit
α-Secretase Activity Kit, TNF-α Converting Enzyme Activity Kit, ADAM17 Activity Kit
ADAM17 Activity Kit, α-Secretase Activity Kit, TNF-α Converting Enzyme Activity Kit
产品介绍:

产品说明

一般描述

The InnoZyme TACE Activity Kit is a specific and sensitive assay designed to measure human TACE activity in cell lysates and biological samples and for screening enzyme inhibitors. An Anti-Human TACE-Coated 96-Well Plate is pre-coated with a monoclonal antibody specific for human TACE that captures the enzyme. Unbound material is discarded, the plate is washed, and the activity of captured TACE is measured using an internally quenched fluorescent substrate, MCA-KPLGL-Dpa-AR-NH2. Cleavage of the scissile amide bond, G-L, releases the fluorophore from the quenching molecule, Dpa, resulting in an increase in fluorescence. Fluorescence of the cleaved product, MCA-KPLG, is measured at an excitation wavelength of ~324 nm and emission wavelength of ~400 nm. The level of fluorescence is directly related to the enzyme activity.

• Highly specific: based on immunocapture of human TACE
• Highly sensitive and quantitative: assay range 5-100 ng/ml
• Convenient: 96-well format and non-radioactive detection
• Versatile: appropriate for measuring active TACE and high-throughput screening of TACE inhibitors

包装

1 kit in Glass bottle

组分

Anti-Human TACE-Coated 96-Well Plate, Control, Substrate, Sample Buffer, Assay Buffer, Wash Buffer, Plate Sealer, and a user protocol.
anti-human TACE-coated 96-well plate, TACE control, substrate, sample buffer, assay buffer, wash buffer, plate sealer, user protocol

警告

Toxicity: Multiple Toxicity Values, refer to MSDS (O)

原理

The InnoZyme TACE Activity Kit is designed to measure human TACE activity in cell lysates and biological samples. The assay may also be used for screening enzyme inhibitors, but the end-user must supply purified enzyme for this application.

制备说明

All reagents necessary to perform the assay are supplied with the kit. Warm all reagents to room temperature (15-25°C) immediately prior to use.For analyzing biological samples the following reagent preparation is required:• Wash Buffer (1X): Dilute Wash Buffer 1:20 with dH2O . To prepare Wash Buffer (1X) for a single wash step for the entire plate, add 2 ml Wash Buffer to 38 ml dH2O. • Control: Dilute the Control with chilled Sample Buffer. Refer to the vial label for lot-specific dilution information.Important Note: Following initial thaw the Control should be dispensed into aliquots and stored at -70°C. Avoid freeze/thaw cycles.• Substrate (1X): Dilute Substrate 1:200 with Assay Buffer. To prepare Substrate (1X) for the entire plate, add 50 µl Substrate to 9.95 ml Assay Buffer.For inhibitor screening the following additional reagent preparation is required:• Test inhibitor(s): Prepare dilutions of test inhibitors in Assay Buffer as necessary.• Diluted Substrate: Dilute Substrate 1:50 with Assay Buffer. To prepare Substrate for the entire plate add 40 µl Substrate to 1.95 ml Assay Buffer.
Dilute samples as necessary with Sample Buffer.Recommended guidelines for sample preparation:1. Total protein concentration in cell lysates should be >5 mg/ml2. Dilution factor for cell lysates at >5 mg/ml is approximately 1:20 or higher

储存及稳定性

Upon receipt the unopened kit should be stored at -20°C or -70°C. All kit components, once opened, can be stored for up to 3 months under the following conditions:



Refrigerate (4°C):

Sample Buffer

Assay Buffer

Wash Buffer

Substrate

Anti-Human TACE-coated 96-well plate



Deep Freeze (-70°C):

Control*



*Note: Following initial use the Control should be dispensed into aliquots and stored at -70°C. Avoid freeze/thaw cycles.

分析说明

The results are displayed in relative fluorescence units (RFU): 1. Correct the fluorescence from each sample and Control by subtracting the fluorescence of the Blank.2. Calculate the mean fluorescence for each sample and Control from duplicate readings to obtain the final RFU.
Positive Control
Human recombinant TACE

其他说明

Kirkegaard, T., et al. 2004. Clin. Exp. Immunol.135, 146.
Neumann, U., et al. 2004. Anal. Biochem.328, 166.
Skovronsky, D.M., et al. 2001. J. Neurobiol.49, 40.
Black, R.A., et al. 1997. Nature385, 729.
Moss, M.L., et al. 1997. Nature385, 733.



Selected Citations
DasGupta S., et al. 2009. Bioorg. Med. Chem.17, 3604.


法律信息

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

产品性质

质量水平100
用途 sufficient for 96 tests
包装pkg of 1 96-well plate(s)
manufacturer/tradenameCalbiochem®
储存条件OK to freeze
avoid repeated freeze/thaw cycles
protect from light
assay rangestandard curve range: 5-100 ng/mL
(as measured with purified recombinant human TACE)
inputsample type cells
detection methodfluorometric
运输wet ice

安全信息

储存分类代码10-13 - German Storage Class 10 to 13

Sigma-Aldrich

推荐产品