您好,欢迎来到试剂仪器网! [登录] [免费注册]
试剂仪器网
位置:首页 > 品牌 > Sigma-Aldrich > Rat/Mouse Ghrelin (total) ELISA

Rat/Mouse Ghrelin (total) ELISA

品牌
Sigma-Aldrich
货号
EZRGRT
规格纯度
This Rat/Mouse Ghrelin (total) ELISA is used to measure & quantify Ghrelin (total) levels in Metabolism & Endocrine research.
参考价格
9841.17 *本价格含增值税费
促销
服务
  • 原厂保证
  • 包邮
  • 增值税票
数量
-+
产品名称:
Rat/Mouse Ghrelin (total) ELISA
产品介绍:

产品说明

一般描述

Circulating ghrelin is a multifunctional hormone secreted primarily by the stomach. Originally found as an endogenous ligand for the growth hormone secretagogue receptor, it is also an appetite-stimulating hormone in the regulation of energy homeostasis. It consists of 28 amino acids and the n-octanoylation of serine-3 position is necessary for its bioactivity. The acylated form is extremely unstable in the blood; consequently, the predominant form is des-octanoyl ghrelin. Long considered a key player in obesity, ghrelin may also play a role in maintaining the balance between insulin and glucose and the development of diabetes. The spike in insulin secretion occurring after eating usually correlates with a dip in ghrelin production. Researchers determined that in rat models of uncontrolled diabetes, food intake still suppressed ghrelin concentrations in the blood, but only approximately half as effectively as when insulin was present.

特异性

Canine Ghrelin (Active) - 71%
Human Ghrelin (Active) - 115%
Human Des-Octanoyl Ghrelin - 249%
Porcine Ghrelin (Active) - 48%
Rat/Mouse Ghrelin (Active) - 85%
Rat/Mouse Des-Octanoyl Ghrelin - 100%

应用

Room temperature, 3 hour assay, 20 μL sample size (serum or plasma)
Research Sub Category
Obesity

Metabolic Disorders
Research Category
Metabolism
Used to detect/quantify: Ghrelin (Total)

其他说明

Please contact Technical Service for linearity of dilution.

免责声明

For research use only. Not for use in diagnostic procedures.

基本信息

eCl@ss32161000
NACRESNA.32

产品性质

质量水平100
species reactivityrat, mouse
assay rangeaccuracy: 80-103%
(Serum: Active Ghrelin)
accuracy: 86-102%
(Plasma: Active Ghrelin)
accuracy: 92-103%
(Serum: Des-octanoyl Ghrelin)
accuracy: 95-107%
(Plasma: Des-octanoyl Ghrelin)
inter-assay cv: 1.8-4.5%
intra-assay cv: 0.7-1.3%
(Serum)
inter-assay cv: 2.0-3.2%
intra-assay cv: 1.1-1.7%
(Plasma)
technique(s)ELISA: suitable
UniProt登记号Q9EQX0 (mouse)
Q9QYH7 (rat)
Q9UBU3
detection methodcolorimetric
fluorometric

安全信息

象形图GHS05GHS06GHS09
警示用语:Danger
危险声明H290 - H302 + H332 - H311 - H315 - H317 - H319 - H335 - H411
预防措施声明P273 - P280 - P301 + P312 - P302 + P352 + P312 - P304 + P340 + P312 - P305 + P351 + P338
危险分类Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3
靶器官Respiratory system
储存分类代码6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGKWGK 3

Sigma-Aldrich

推荐产品