产品说明
一般描述
Introduction:
Cell adhesion plays a major role in cellular communication and regulation, and is of fundamental importance in the development and maintenance of tissues. Scientists are continually examining the adhesion, migration, and invasion of many diverse cell types on various extracellular matrix (ECM) component proteins. The CHEMICON
In addition, Chemicon continues to provide numerous migration, invasion, and adhesion products including:
· Alpha Integrin-Mediated Cell Adhesion Array Kit (Colorimetric) (ECM530)
· Beta Integrin-Mediated Cell Adhesion Array Kit (Colorimetric) (ECM531)
· Alpha/Beta Integrin-Mediated Cell Adhesion Array Combo Kit (Colorimetric) (ECM532)
· Alpha Integrin-Mediated Cell Adhesion Array Kit (Fluorimetric) (ECM533)
· Beta Integrin-Mediated Cell Adhesion Array Kit (Fluorimetric) (ECM534)
· Alpha/Beta Integrin-Mediated Cell Adhesion Array Combo Kit (Fluorimetric) (ECM535)
· ECM Cell Adhesion Array Kit (Fluorimetric) (ECM545)
· QCM
· QCM
· QCM
· QCM
· QCM
· 24-well Insert Cell Migration and Invasion assay systems
· CytoMatrix
· QuantiMatrix
Test Principle:
The CHEMICON
Additional information about the ECM components provided in the kit:
包装
1 plate in 96 wells
96 wells
应用
Research Category
Cell Structure
The CHEMICON
For Research Use Only. Not for use in diagnostic procedures.
组分
ECM Array Plate: (PN: 90652) One 96-well plate with 12 strips. Each 8-well strip consists of 7 different human, ECM protein-coated wells (Collagen I, Collagen II, Collagen IV, Fibronectin, Laminin, Tenascin, Vitronectin) and one BSA-coated well (negative control). See the plate layout on Data sheet.
Cell Stain Solution: (Part No. 90144) One bottle - 20 mL.
Extraction Buffer: (Part No. 90145) One bottle - 20 mL.
Assay Buffer: (Part No. 90601) One bottle - 100 mL.
储存及稳定性
The ECM Array Plate can be stored at 2° to 8°C in the foil pouch up to its expiration date. Unused strips may be placed back in the pouch for storage. Ensure that the desiccant remains in the pouch, and that the pouch is securely closed. Keep the remaining kit components at 2° to 8°C.
Precautions:
· Cell stain contains minor amounts of crystal violet, a toxic substance, which may cause cancer and heritable genetic damage. Handle with caution. Toxic by inhalation and if swallowed. Irritating to eyes, respiratory system and skin.
· Extraction buffer contains alcohol. Avoid internal consumption.
法律信息
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
免责声明
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
基本信息
eCl@ss | 32161000 |
NACRES | NA.32 |
产品性质
质量水平 | 100 |
species reactivity | human |
manufacturer/tradename | Chemicon® |
technique(s) | cell based assay: suitable |
detection method | colorimetric |
运输 | wet ice |
Sigma-Aldrich