产品说明
一般描述
TMB, (3,3′,5,5′-tetramethybenzidine) has been shown to be a safe-sensitive substrate for the assay of HRP. Initially, in the presence of HRP and hydrogen peroxide, a one-electron oxidation product is formed. This compound, a cation free radical, is blue in color with an adsorption maximum of 653 nm. Further reaction with HRP/H2O2 or acidification of the radical with acid yields the diimine terminal oxidation product adsorbing light at 450 nm. The extinction coefficient of the radical (E653nm=3.9 x 104 mol-1 cm-1) and diimine (E450nm=5.9 x 104 mol-1 cm-1) provide a remarkably sensitive system for the assay of HRP and HRP labeled probes. ES022 is a single component reagent stable at room temperature and not sensitive to normal laboratory light. It is optimized with respect to TMB and hydrogen peroxide concentrations and yields a linear response with the concentrations of HRP usually employed in immunological assays.
应用
METHOD SYNOPSIS:
After completion of analyte binding to a solid phase and reaction with a HRP labeled probe, ES022 is added. Oxidation of TMB produces a blue reaction product that is measured at 650 nm. The color formation as a function of time can be recorded or the reaction stopped with sodium fluoride after a fixed interval. Increased sensitivity can be achieved by converting the blue radical to the diimine by addition of acid. The resulting yellow color is measured immediately at 450 nm.
SAMPLE PROCEDURE:
1. Complete all required incubations with antibodies, probes, HRP labeled reagents.
2. Wash plate at least 4 times with PBS or Tris buffered saline containing 0.1% Tween-20.
3. After the final wash, shake and blot all residual buffer from plate wells.
4. Add 0.1 mL of ES022 (TMBE Solution) to appropriate wells and incubate 5-30 minutes.
Note: The reaction time will depend upon the activity of the HRP probe. If color develops too briskly, zero order kinetics will not prevail. Dilution of the probe, antibody or HRP labeled reagent may be required.
5. The reaction can be monitored as a function of time for kinetic assays or stopped with 0.1 mL of 0.3 Mol/L of sulphuric acid or 0.1% sodium fluoride and read at 450 nm.
6. If the procedure demands conversion to the yellow diimine, add 0.1 mL of either acid described in the reagent section above and record the absorbance within 5 minutes.
Variations of time, reagent volume and temperature require standardization by the user.
外形
REAGENT PROVIDED:
Liquid solution containing TMB, 2.08 μMol L(-1) and Hydrogen Peroxide, citric acid buffer at pH 3.3. Also contains non-toxic proprietary stabilizers.
MATERIALS REQUIRED: Reagents Required for Stopping the Reaction, But Not Provided
A. 0.3 Mol L sulphuric acid for stopping the reaction and preserving blue chromogen.
Note: Reagent grade water must contain less than 10(-7) Mol/L of iron or copper salts otherwise unreacted TMB will be converted non-enzymatically to the diimine.
Color Code: 黄色
储存及稳定性
Maintain at room temperature for up to six months. For long term storage, up to twelve months, maintain at 2-8°C. Protect from exposure to direct sunlight. Discard if solution is blue or turbid.
Warm to room temperature prior to use.
REAGENT PROVIDED: Liquid solution containing TMB, 2.08 mMol L(-1) and Hydrogen Peroxide, citric acid buffer at pH 3.3. Also contains non-toxic proprietary stabilizers.
法律信息
CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
免责声明
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
基本信息
eCl@ss | 42029053 |
NACRES | NB.22 |
产品性质
质量水平 | 100 |
manufacturer/tradename | Chemicon® |
technique(s) | ELISA: suitable immunohistochemistry: suitable |
λmax | 450 nm |
运输 | wet ice |
安全信息
储存分类代码 | 12 - Non Combustible Liquids |
WGK | WGK 1 |
闪点(F) | Not applicable |
闪点(C) | Not applicable |